Accessories & Ancillaries

Pentair WellMate Pressure Tanks Indonesia

Select a Pentair WellMate pressure tank from drawdown, cut-in/cut-out, precharge, pressure, and pump duty with PT Watermart Perkasa for Indonesian projects.

Interested?

Contact our team for specifications and availability.

WhatsApp us

Short answer: Pentair WellMate pressure tanks are used in well, booster and hydropneumatic systems. Select the capacity from the drawdown you need, the pump flow and the minimum run time, the cut-in/cut-out pressure, the precharge and the model pressure limit. A WellMate is not an FRP vessel filled with filter media or resin. See FRP filter and softener vessels for that duty.

PT Watermart Perkasa, operating at water.co.id, supplies Pentair WellMate in Indonesia for domestic, commercial, agricultural and process-water systems. Options include WM, UT, HP and SP series, in-line tanks, micronizers and accessories. Confirm the final model against pump data, pressure-switch settings, connections, space, and current Pentair catalogues and manuals.

What data are needed to select a WellMate?

Total tank capacity is not the same as the usable water volume between cut-in and cut-out. Use the drawdown at the correct pressure range. Then check the pump minimum run time and the vessel pressure limit.

System dataDecision affected
Pump flow and minimum run timeDrawdown target that limits excessive pump cycling
Cut-in and cut-out pressureDrawdown factor and operating range
Actual prechargeUsable water volume and pressure-switch response
Maximum working pressureVessel series and margin for abnormal conditions
Diameter, height, and connectionPlant-room fit, pipework, and installation orientation
System dutyWhether WM, UT, HP, SP, or an in-line series should be assessed

Pentair WellMate series and manufacturer data

pentairwellmate

Advantages of WellMate Products for Water Treatment Systems

  • Corrosion-resistant composite construction: Check model suitability against the water and plant-room conditions.
  • Installation weight: The catalogue lists the weight of each model for transport and support planning.
  • Model certification: Match the listed NSF/ANSI or other certification for the model to project requirements.
  • Drawdown data: Use the value for the correct cut-in/cut-out range, not the nominal tank capacity.
  • Maintenance: Follow the manual checks for precharge, leakage, pressure switch and relief device.

1. WellMate Composite Pressure Tanks (WM, UT, HP, SP Series)

WellMate composite pressure tanks come in several series and capacities. They are used for water storage, pressure boosting, water treatment and hydropneumatic applications. Each model is made for the needs of domestic, commercial and agricultural water systems.

ModelCapacity (Gal/L)Max Operating Pressure (psi/bar)Drawdown 30/50 (Gal/L)Diameter (in/cm)Height (in/cm)System Connection (Top/Bottom)Weight (lbs/kg)
WM-414.5 / 55125 / 8.64.5 / 17.016 / 4126 / 661″ MNPT Top17.7 / 8.1
WM-925.9 / 112125 / 8.69.1 / 34.416 / 4144 / 1121″ MNPT Top27 / 12.2
UT-3030 / 11475 / 5.016 / 4115 / 3846 / 118.81-1/4” Socket QC23 / 10.4
UT-8080 / 30375 / 5.021 / 5326 / 6664.2 / 163.21-1/4” Socket QC53 / 24.0
HP-730 / 11475 / 5.06.6 / 25.016 / 4145.2 / 115.61-1/4” Vent Line / 1-1/4” Socket24 / 10.9
HP-1880 / 30375 / 5.017.8 / 67.421 / 5363.7 / 161.91-1/4” Vent Line / 1-1/4” Socket55 / 24.9
SP-940 / 151100 / 7.09 / 3416 / 4156.5 / 1441-1/4” Socket (T/B)35 / 15.9
SP-1880 / 303100 / 7.018 / 6721 / 5362 / 1571-1/4” Socket (T/B)67 / 30.5

For full specifications and other models, please download the following product catalog: Download wm900-composite-pressure-tank-cat.pdf

Main Applications:

  • Water storage and pressure boosting
  • Water treatment systems (buffer tanks, chemical dosing, iron/sulfur removal)
  • Hydropneumatic installations
  • Agricultural and irrigation
  • Commercial and residential plumbing systems

2. WellMate Drawdown Factors - Residential Tank Sizing Calculator

Pressure-tank sizing depends on the drawdown you need. The WellMate Drawdown Factors Residential Tank Sizing Calculator gives drawdown factors based on Boyle’s law for the listed cut-in/cut-out and precharge combinations.

  • Pressure range: 20-125 PSIG
  • Drawdown factor table for several pressure combinations
  • Industry standard reference for booster system design, well bore and hydropneumatic applications

Download the full sizing calculator datasheet here: Download WellMate_TankSizingCalculator_DrawdownFactors.pdf

Drawdown Factors Table Example

Maximum System Pressure (PSIG/kPa/bar)Minimum System Pressure (PSIG/kPa/bar)20 (138) 1.3825 (173) 1.7230 (207) 2.0635 (242) 2.4140 (276) 2.7645 (311) 3.1050 (345) 3.45
30 (207) 2.060.21
35 (242) 2.410.280.19
40 (276) 2.760.340.260.17

Notes: The drawdown factor is based on Boyle’s law. However, actual values may vary depending on system conditions, pressure switch and gauge accuracy, precharge pressure and temperature.

3. WellMate In-Line Pressure Tanks (WM01 & WM02)

WellMate WM01 and WM02 In-Line Pressure Tanks are compact pressure tanks for domestic borehole systems and booster pumps. They have a replaceable air charge valve, a butyl diaphragm and a epoxy-coated steel shell that is light and does not rust.

SpecificationWM01WM02
Volume (US gal/L)2.0 gal (7.6 L)4.6 gal (17.4 L)
Drawdown (20-40 PSI)0.7 gal (2.6 L)1.7 gal (6.1 L)
Drawdown (30-50 PSI)0.6 gal (2.3 L)1.5 gal (5.3 L)
Precharge Pressure20 PSI (138 kPa)20 PSI (138 kPa)
Max Working Pressure100 PSI (690 kPa)100 PSI (690 kPa)

For the full datasheet, please download: Download wm01-inlinepressuretank-mr14-ds.pdf

Application:

  • Private residential wells
  • Booster pump systems
  • Water pressure stabilization for irrigation

4. WellMate Micronizer - Continuous Air Charging Device

Pentair WellMate Micronizer is a venturi-based air charging device. It is mounted on a hydropneumatic system to keep the air volume in the pressure tank at the right level. It is made of PVC that does not corrode, it is easy to set up without tools, and it fits all WellMate tanks.

  • Pipe size: 1” male NPT
  • Operating flow: 5-15 gpm
  • Working pressure: 10-60 psi
  • Hand-adjustable air draw setting

Download the micronizer datasheet here: Download wm107-micronizer-mr14-ds.pdf

5. WellMate Base Extender - Tank Height Increase Platform

The Pentair WellMate Base Extender raises listed 16-inch-diameter tanks when pipe alignment or service access needs more height. Check the supported model and the load before you stack or install it.

Model NumberCompatible TanksSupported Tank WeightDiameterOverall HeightWorking HeightMaterial
CH14743All 16” diameter tanks, WM-6LP, WM-10LPUp to 330 lbs (149.7 kg)16.74” (40 cm)5.31” (13.5 cm)3.9” (9.6 cm)Polymeric, high-impact, corrosion-resistant

Download the base extender datasheet: Download wm303-baseextender-mr14-ds.pdf

6. WellMate Installation & Maintenance Guide

PT Watermart Perkasa gives technical support for WellMate selection in Indonesia. The Pentair installation instructions for the UT, HP and SP Series cover installation, precharge settings, pressure-relief provision, troubleshooting and periodic maintenance.

  • Make sure the tank sits on a flat and firm surface
  • Use flexible connectors to avoid vibration
  • Set precharge pressure 4 psi below cut-in pressure
  • Check air pressure and leaks regularly

Download the complete installation manual: Download w3720-tank-instructions-mr14.pdf

Why Choose WellMate from PT Watermart Perkasa?

  • Series selection based on pump data, drawdown, pressure and space
  • Pentair product documents for checking model specifications
  • Technical support and tank sizing consultation by an experienced team
  • Tank, accessories and supporting devices for the selected configuration

Download All WellMate Datasheets & Manuals

Contact PT Watermart Perkasa

For technical consultation, a quotation or a WellMate order, send the pump, pressure, drawdown and space data through the PT Watermart Perkasa contact page.

PT Watermart Perkasa supplies Pentair WellMate and helps buyers prepare the initial data for pressure-tank selection in Indonesia.

WhatsApp