Iron and manganese filter media in Indonesia: GreensandPlus, Clack Birm and Tohkemy Ferrolite. Compare oxidant, pH, service flow and backwash, then send a water test for a quote.

Iron and Manganese Media: GreensandPlus, Birm, Ferrolite

PT Watermart Perkasa supplies three iron and manganese filter media in Indonesia: GreensandPlus (Inversand), which uses chlorine or another oxidant; Clack Birm, which uses dissolved oxygen without chemicals; and Tohkemy Ferrolite, which uses chlorine dosing. The choice depends on pH, H₂S, Fe and Mn levels, the available oxidant and backwash capacity, so start with a water test.

This page helps buyers prepare the evidence needed to check the media, vessel, valve and distributor as one set of components. The full comparison is in the greensand vs Birm vs Ferrolite article.

Updated 12 November 2026: this page now summarises the three iron-manganese media using current manufacturer datasheets; GreensandPlus operating data is on the GreensandPlus page.

Iron and manganese filter media for water-treatment systems

GreensandPlus, Birm or Ferrolite: which media should be evaluated?

ParameterGreensandPlusClack BirmFerrolite (Tohkemy)
OxidantChlorine or another strong oxidant, also permanganateDissolved oxygen (at least 15% of Fe and 29% of Mn); no regeneration chemicalsChlorine or sodium hypochlorite dosing
Contaminants named by the makerFe, Mn, H₂S, arsenic, radiumFe and/or MnHigh-concentration Fe and Mn
pH6.2–8.56.8–9.0 (Mn: 8.0–9.0)Preferably > 6.5
Key limitsChlorine demand calculated from Fe, Mn, H₂S and NH₃Free chlorine < 0.5 ppm; no H₂S, oil or polyphosphateChlorine demand rises with organics or ammonia
Service flow4.9–29.4 m/h3.5–5 gpm/ft² (≈ 8.6–12.2 m/h)10–30 m/h
Bed depth762 mm alone; 381 mm of each media in dual media30–36 in. (≈ 76–91 cm)About 1.2 m
BackwashAt least 29.4 m/h (12 gpm/ft²) at 12.78°C10–12 gpm/ft² (≈ 24.4–29.3 m/h)No figure given

Sources: GreensandPlus Technical Data Sheet Rev. 5/25, Clack Birm Form No. 2350 and the Tohkemy filter media catalogue, accessed 12 November 2026. Birm unit conversions are ours. Manufacturer values are selection and operating conditions, not a guarantee for every source water.

Other Clack or Tohkemy media still need a model-specific data sheet and the same water-test evidence; a brand name is not enough to approve a substitution.

What determines the price of iron and manganese media?

The price of GreensandPlus, Birm or Ferrolite depends on media quantity, packaging, lot availability, delivery location, support-media needs, and whether the buyer needs media only or also vessels, valves, distributors, and commissioning. Compare quotations at the complete filter level, not only per bag, because incorrect backwash sizing can stop the media from performing as intended.

Price factorInformation to provideQuotation impact
Media quantityVessel diameter, bed depth, freeboard, unit count, and spare volumeSets total bags or pallets and logistics cost
Supply scopeMedia only, support bed, FRP vessel, valve, distributor, media loading, or commissioningMakes supplier prices commercially comparable
Water dataIron, manganese, pH, H2S, dissolved oxygen, oxidant, turbidity, and filtrate targetConfirms which media is the right path
BackwashFlow, duration, temperature, pump capacity, and drain capacitySets filter size and the risk of media loss to drain
Site and timingProject city, delivery access, quantity, and required dateDetermines freight, lead time, and quotation documents

Send these details through the Watermart contact page to request pricing. Buyers should also compare Inversand GreensandPlus with Clack Birm when the water test still leaves several media options open.

How to request a GreensandPlus quotation

A GreensandPlus quotation should separate replacement-media purchases from a complete filter-system supply. For replacement media, send old media volume, label photos, vessel diameter, bed depth, and the latest operating issue. For a new system, send water-test results, design flow, outlet target, installation space, backwash drain, and commissioning needs.

RequirementData that speeds up review
Replacement mediaVolume, old media brand/model, media age, differential pressure, filtrate result, and vessel photos
New filter systemComplete water test, normal/peak flow, quality target, oxidant, vessel, valve, distributor, and backwash
Stock or phased project purchaseBags or pallets, delivery location, required date, and requested lot documents

Watermart confirms availability, packaging, product documents, and quotation scope when the request is received. Do not select media as a shortcut when backwash flow, oxidation, or wash-water disposal is not ready.

When should buyers order media only or other filter components too?

Direct answer: order GreensandPlus as media only when the existing filter is already proven hydraulically and chemically suitable. If the vessel, valve, distributor, oxidation step, or drain is uncertain, quote those components together so the media does not fail because of poor backwash, contact time, or valve sequencing. Assembled filter systems are handled by our sister company PT Beta Pramesti Asia at beta.co.id.

Project conditionSafer scopeEvidence before quotation
Replacement media for an existing filterMedia, support media, loading service, and limited commissioningVessel diameter, bed depth, freeboard, distributor, actual backwash flow, and old-media photos
New well water with high Fe/MnMedia, FRP vessel, valve, oxidation, drain, and samplingNew water test, well flow, outlet target, drain location, installation space, and operating schedule
Pretreatment before ROGreensandPlus or another medium, cartridge filter, dosing, and RO membranesFe/Mn after filtration, SDI/turbidity, chlorine, pressure, and RO reject plan
Automatic systemMedia plus Aquamatic valve or a suitable control valveService-backwash-rinse sequence, pilot pressure, interlocks, drain, and fail-safe position

What Water-Test Data Should a Buyer Send?

Send a representative laboratory result before selecting media. For groundwater that changes by season or pumping period, one old result may not represent the design condition.

  1. Total and dissolved iron, total and dissolved manganese, pH, turbidity, colour, TDS, and alkalinity.
  2. Hydrogen sulphide or odour, residual chlorine, oil, and any phosphate or other chemical addition.
  3. Normal and peak flow, operating hours, daily volume, inlet pressure, and treated-water target.
  4. Vessel diameter and height, bed depth, freeboard, support media, and bottom-distributor type.
  5. Available backwash flow and duration, water temperature, pump capacity, and drain capacity.
  6. Existing media label, valve model, unit quantity, project location, and installation-space limits.

See the media-filtration application for the process context. Buyers can also compare Inversand GreensandPlus, Clack Birm, FRP filter vessels, and the broader filter-media range.

How Should Filter Size and Backwash Be Checked?

Vessel area, service loading, and backwash loading must be calculated in consistent units. Flow alone is insufficient: too little backwash may not clean the bed, while excessive flow can carry media to drain. Use the actual internal diameter and the media expansion curve at the project water temperature.

Before changing media in an existing unit, record clean differential pressure, flow, filtrate quality, run length, and distributor condition. If the new medium has a different density or size, do not assume that the old valve settings, backwash duration, or freeboard remain suitable.

FAQ about iron and manganese media

Can Birm and GreensandPlus be substituted for one another?

Not automatically. Their water-chemistry and operating requirements differ. Verify pH, oxygen or oxidant, interfering contaminants, media size, backwash demand, and product instructions before changing media.

What is the difference between GreensandPlus, Birm and Ferrolite?

GreensandPlus uses chlorine or another oxidant and also handles H₂S; Birm uses dissolved oxygen without chemicals but must not see free chlorine above 0.5 ppm or H₂S; Ferrolite uses chlorine dosing for high Fe and Mn. See the full table in the comparison article.

Which media should be used for yellow well water?

Yellow colour does not identify the cause. Test iron, manganese, colour, turbidity, pH, and related parameters first; organic matter, pipe corrosion, or sediment may require a different process.

Does this media make water ready to drink?

No. Equipment or media selection alone does not prove that water is safe to drink. A drinking-water system must meet applicable Indonesian requirements, be commissioned and sanitised, maintain consumables records, and be verified through representative sampling and laboratory testing.

Where can buyers request iron and manganese filter media in Indonesia?

Send the water test, flow, vessel, backwash, quantity, and project location through the Watermart contact page. PT Watermart Perkasa will check specification fit and availability at the time of quotation.